  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
07/18/2023
Sold Price
$418,000$254/ft²

3948 S 24th Ave
Minneapolis, MN 55406

3948 S 24th Ave, Minneapolis, MN 55406 is a 3 bed, 2 bath, 1,645 ft² house built in 1927 on a 0.110 acre lot with 21 construction permits. This house is currently off market, and it was last sold in 2023 for $418,000. The latest TopHap estimate of the house's value is $360,441.

Property Valuations

Latest estimates for 3948 S 24th Ave based on TopHap automated valuation model (AVM).

Permits

3948 S 24th Ave has 21 permit records of total value of $57,659.

Permit History
21
Permits
$57,659
Total Permit Value
September 15, 2016
Description: Replace one pre-hung rear doorJob Value: $977Status: OpenType: Building over the counterSub Type: BotcBusiness Name: Crew2 IncApplicant: Brent BatemanFees: $81Effective Date: 2016-09-15Permit Number: 1131030
September 15, 2016
Job Value: $977Status: filedType: ResidentialBusiness Name: Crew2 IncApplicant: Brent J Bateman0Effective Date: 2016-09-15Permit Number: BLDG167073
January 4, 2016
Description: Convert existing duplex to single family residence. No demolish or construction. (wss)Job Value: $500Status: OpenType: RemodelingSub Type: BireBusiness Name: Brent J BatemanApplicant: Brent BatemanFees: $81Effective Date: 2016-01-04Permit Number: 3102316
September 27, 2013
Description: *IRC2-ADD CONSTRUCT 22' WIDE 2ND FLOOR DORMER ADDITION AT SIDE YARD OF DUPLEX DWELLING FOR (DMH#2) OFFICE, BATHROOM AND BEDROOM ADDITION. INSTALL FULL HEIGHT WALLS, ROOF TRUSSES AND STUCCO EXTERIOR. INSTALL NEW RIDGE BEAM AND BEARING PER ATTACHED ENGINEERING. PROTECTED WALL AT NORTH ELEVATION. NO DISRUPTION TO FIRE/SOUND. THIS PROPERTY FUNCTION AS SFD WITH DUPLEX STATUS. ENGINEER OF RECORD: TREVOR AXNER, 45470 FIRE RATING: Walls, soffits, and fascia closer than 5 feet to property lines must be protected on the interior and exterior face with 5/8" exterior gypsum sheathing, stucco or other approved materials for fire resistance. This requirement does not apply to the wall facing a city alley. EAVES AT COMMON PROPERTY LINES: Where exterior walls are approved at a setback of 2 feet or less from a property line, eaves of not more than 4" are permitted. EAVES ALONG ALLEY PROPERTY LINE: Eaves along alley are not to be closer than 6" to alley right-of way (property stake) OPENINGS: (windows, Status: finalType: ResidentialApplicant: Brent J BatemanEffective Date: 2013-09-27Permit Number: BLDG35659
September 6, 2013
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets__1__ Urinals_____ Bath Tubs_1___ Basins__1__ Sinks_____ Wash Trays__1___ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters_____ Other: Specify below GAS DRYER Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf Plans approved by both the State of MinneStatus: finalType: PlumbingApplicant: Brent J BatemanEffective Date: 2013-09-06Permit Number: BLDG479495
September 3, 2013
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: REROUTE EXISTING VENTS TO DISTRIBUTE HEAT/A/C TO NEW ROOMS Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air conditioning or which has no windows or doors in the wall immediately abutting the yard. Such equipment may project into a corner side yard, provided such equipment is located no closer than three (3) feet from the corner side lot line. In no case shall any permitted obstruction be located closer than one (1) foot from the property Status: finalType: MechanicalApplicant: Brent J BatemanEffective Date: 2013-09-03Permit Number: BLDG320624
April 9, 2012
Project Name: Saver SwtStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Hunt Electric CorporationApplicant: Scott SanvilleFees: $40Effective Date: 2012-04-09Permit Number: ELE1202-05255
January 7, 2012
Description: (6/17/2011 8:53 am kgr) 2nd floor expansion/remodel. Will be funning a 60a feeder off main panel to a sub panel on the 2nd floor. This sub panel will supply circuits for 1 bedroom 1 bathroom 1 office and 1 small laundry. I would also like to run a whole house vent fan from this panel. Dryer in laundry will be gasStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstApplicant: Scott SanvilleFees: $77Effective Date: 2012-01-07Permit Number: ELE1106-12892
June 10, 2011
Description: Reroute existing vents to distribute heat/a/c to new roomsStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Scott W SanvilleApplicant: Scott W SanvilleFees: $74Effective Date: 2011-06-10Permit Number: 4098891
June 10, 2011
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Scott W SanvilleApplicant: Scott W SanvilleFees: $252Effective Date: 2011-06-10Permit Number: 5129151
April 8, 2011
Description: Construct 22 wide 2nd floor dormer addition at side yard of duplex dwelling for (dmh#2)Job Value: $35,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Scott W SanvilleApplicant: Scott W SanvilleFees: $1,073Effective Date: 2011-04-08Permit Number: 3070506
March 29, 2011
Description: This permit authorizes the replacement of 6 windows inserts in same openingsJob Value: $4,500Status: DoneType: Building over the counterSub Type: BotcBusiness Name: The Window Store Home Improvements IncApplicant: Scott W SanvilleFees: $145Effective Date: 2011-03-29Permit Number: 1092076
November 16, 2007
Description: R3/REM REBUILD EXISTING 2ND FLOOR REAR DECK WITH STEPS OF EXISTING DUPLEX. AAJ#2 - DEMO EXISTING REAR DECK AND INSTALL NEW 5' X 7' DECK WITH STEPS, USING 2 X 8 FLOOR JOISTS AND RIMS. - INSTALL 2 - 4 X 4 TREATED POSTS WITH 10" DIAMETER FROST DEPTH CONCRETE FOOTINGS. - INSTALL 5/4" TREATED WOOD DECKING BOARDS. - INSTALL STEPS, GUARD AND HAND RAIL TO CODE REQUIREMENT. CALL 651-454-0002, 48 HOURS BEFORE DIGGING FOR GOPHER STATE ONE CALL. SEE PLAN FOR DETAILED SCOPE OF WORK TO BE DONE AS WELL AS PLAN REVIEW COMMENTS. CONTRACT PROVIDED FOR CODE COMPLIANCE AND FIRE REPAIRS___N/A___ SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. R317.1.1 Alterations, repairs or additions. When interior alterations, repairs or additions requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarStatus: finalType: CommercialApplicant: Brent J BatemanEffective Date: 2007-11-16Permit Number: BLDG229255
October 10, 2007
Description: Rebuild existing 2nd floor rear deck with steps of existing duplex. Aaj#2Job Value: $4,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Wonderwoman Construction LlcApplicant: Scott W SanvilleFees: $189Effective Date: 2007-10-10Permit Number: 3050119
October 23, 1995
Description: Misc rpr:valley workJob Value: $730Status: DoneType: BuildingSub Type: BApplicant: Brent Bateman0Effective Date: 1995-10-23Permit Number: 624263
December 7, 1994
Description: Rpl reroof w/tearoff-house residenceJob Value: $3,890Status: DoneType: BuildingSub Type: BApplicant: Brent Bateman0Effective Date: 1994-12-07Permit Number: 614783
April 26, 1994
Description: Rpr flash/counter flash w steel 2dormer & 1 chimxJob Value: $1,200Status: DoneType: BuildingSub Type: BApplicant: Brent Bateman0Effective Date: 1994-04-26Permit Number: 606957
January 1, 1900
Description: Replace one prehung entry doorJob Value: $885Status: completeType: ResidentialBusiness Name: Crew2 INCApplicant: Brent J BatemanFees: $85Effective Date: 1900-01-01Permit Number: BLDG817479
January 1, 1900
Description: *irc1-r/r convert existing duplex to single family residence. No demolish or construction. (wss) separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into tJob Value: $500Status: completeType: ResidentialBusiness Name: Brent J BatemanApplicant: Brent J BatemanEffective Date: 1900-01-01Permit Number: BLDG52016
January 1, 1900
Description: *irc-wndow this permit authorizes the replacement of 6 windows inserts in same openings 1. For one- or two-family dwellings windows installed under this permit shall meet the requirements of the current minnesota state residential code. 2. For buildings with three or more dwelling units windows installed under this permit shall meet the requirements of the current minnesota state building code international building code section 1026. 3. Emergency escape and rescue windows are normally required in sleeping rooms. The requirements for these windows are complex. If you did not have a plan review performed by the city and have not spoken with a qualified person regarding these requirements it is recommended that you do so before purchasing or installing emergency escape and rescue windows. All replacement windows installed in a rental property or licensed facility (state or locally licensed) must meet the requirements of the most current minnesota state building code excluding irc sectionJob Value: $4,500Status: completeType: ResidentialBusiness Name: THE Window Store INCApplicant: Brent J BatemanEffective Date: 1900-01-01Permit Number: BLDG122631
January 1, 1900
Description: Meter move q4 - 2021 batch #11Status: completeType: plumbingBusiness Name: Center Point Energy Resource CorpApplicant: Brent J BatemanFees: $85Effective Date: 1900-01-01Permit Number: BLDG944827

Current Ownership

Information about the current owner(s).

Property History

3948 S 24th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 3948 S 24th Ave

School Information

Public/private schools serving 3948 S 24th Ave

Neighborhood

This property is located in Standish, Minneapolis, MN 55406.

Market Trends

Historical market data near 3948 S 24th Ave over selected time period.

Nearby Properties on 24th Ave