?
  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Off-Market
Sold Price
$--$--/ft²

1816 Ne 19th Ave
Minneapolis, MN 55418

1816 Ne 19th Ave, Minneapolis, MN 55418 is a 3 bed, 2 bath, 936 ft² house built in 1950 on a 0.140 acre lot with 17 construction permits. This house is currently off market. The latest TopHap estimate of the house's value is $273,866.

Property Valuations

Latest estimates for 1816 Ne 19th Ave based on TopHap automated valuation model (AVM).

Permits

1816 Ne 19th Ave has 17 permit records of total value of $14,557.

Permit History
17
Permits
$14,557
Total Permit Value
January 20, 2015
Description: HVAC-LVL3 | Scope of work: HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: _YES_Remove existing system and install new (boiler or forced air system) REPLACE GRAVITY SYSTEM WITH FORCED AIR - CARRIER 60000 BTU/95% EFFICIENCY FURNACE AND 2 TON/13 SEER A/C INCLUDES NEW DUCTWORK __Install a new system to serve an existing non-conditioned space or addition REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the proper Minneapolis installer cStatus: completeType: MechanicalBusiness Name: Residential Htg & A / C IncApplicant: Bridget LeeEffective Date: 2015-01-20Permit Number: BLDG332031
January 21, 2014
Project Name: Res HeatDescription: FurnaceStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: ST Joseph Electric INCApplicant: Bridge LeeFees: $40Effective Date: 2014-01-21Permit Number: ELE1310-01258
October 4, 2013
Description: HVAC work and entire system replacementStatus: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Residential Htg & A/c, IncApplicant: Bridget LeeFees: $207Effective Date: 2013-10-04Permit Number: 4104693
August 8, 2013
Description: Specify the type of fixtures by entering the quantity in the list below:Status: OpenType: plumbingSub Type: BtpaBusiness Name: David P LindemanApplicant: Bridget LeeFees: $84Effective Date: 2013-08-08Permit Number: 5155585
August 8, 2013
Description: Specify the type of fixtures by entering the quantity in the list below: Water Closets____ Urinals_____ Bath Tubs____ Basins____ Sinks_____ Wash Trays__1___ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materialsStatus: OpenType: Plumbing PermitSub Type: PlumbingBusiness Name: DAVID P LINDEMANApplicant: BRIDGET LEEFees: $84Effective Date: 2013-08-08Permit Number: BLDG506859
July 13, 2013
Description: *irc1-r/r partial basement finish for new bathroom and bar area and replace bathroom window at single family dwelling (jag # 2) separate permits are required for electrical plumbingand heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior whicStatus: finalType: ResidentialApplicant: Bridget LeeEffective Date: 2013-07-13Permit Number: BLDG37247
July 11, 2013
Description: *irc1-r/r install basement egress window per department bulletin. Lbf this permit for an egress window in no way allows creation of an additional dwelling unit nor does it make a basment bedroom legal that was built without a permit. Additional permits are required for other modifications to the basement such as adding a bedroom or a dwelling unitStatus: finalType: ResidentialApplicant: Bridget LeeEffective Date: 2013-07-11Permit Number: BLDG34081
August 25, 2011
Description: plumbingfix specify the type of fixtures by entering the quantity in the list below: water closets__1__ urinals_____ bathroom tubs____ basins__1__ sinks__1___ wash trays_____ showers__1___ floor drains____ extensions_____ misc fixtures____ electric water heaters_____ other: specify below properly plug the unused plumbingopenings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbingmaterials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbingcontractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf plans approved by both the state of minnesoStatus: finalType: PlumbingApplicant: Bridget LeeEffective Date: 2011-08-25Permit Number: BLDG504064
August 25, 2011
Description: plumbing45 water piping properly plug the unused plumbingopenings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbingmaterials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbingcontractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf plans approved by both the state of minnesota department of health and the department of labor and industry are required to be on site for all plumbingwork conducted in hospitals nursing homes supervised living facilities outpatient surgical centers boarding care homes and residential hospice facilitiesStatus: finalType: PlumbingApplicant: Bridget LeeEffective Date: 2011-08-25Permit Number: BLDG528093
June 29, 2011
Description: 45 water pipingStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Patricki PlumbingApplicant: Bridget LeeFees: $79Effective Date: 2011-06-29Permit Number: 5129576
June 1, 2011
Description: Partial basement finish for new bathroom and bar area and replace bathroom window at single family dwelling (jag # 2)Job Value: $6,000Status: DoneType: RemodelingSub Type: BireBusiness Name: David P LindemanApplicant: Bridget LeeFees: $239Effective Date: 2011-06-01Permit Number: 3071599
May 24, 2011
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Patricki PlumbingApplicant: Bridget LeeFees: $151Effective Date: 2011-05-24Permit Number: 5128730
October 1, 2010
Description: Install basement egress window per department bulletin. LbfJob Value: $1,500Status: DoneType: RemodelingSub Type: BireBusiness Name: David P LindemanApplicant: Bridget LeeFees: $73Effective Date: 2010-10-01Permit Number: 3067910
October 6, 2004
Description: Upgrade service to 200 amp with 10 circuits (6 are new circuits)Status: DoneType: ElectricalSub Type: BteaBusiness Name: Cornish Steve MApplicant: Bridget LeeFees: $156Effective Date: 2004-10-06Permit Number: 1071720
October 18, 1993
Description: Alter misc code corrections for certification residenceJob Value: $680Status: DoneType: ElectricalSub Type: FApplicant: Bridget Lee0Effective Date: 1993-10-18Permit Number: 869500
January 1, 1900
Description: Meter move q2 - 2021 batch #4Status: completeType: plumbingBusiness Name: Center Point Energy Resource CorpApplicant: Lawrence F De NucciFees: $85Effective Date: 1900-01-01Permit Number: BLDG924485
January 1, 1900
Description: Remove and replace shingles on house roofJob Value: $6,377Status: completeType: ResidentialBusiness Name: ALL Elements INCApplicant: Lawrence F De NucciFees: $210Effective Date: 1900-01-01Permit Number: BLDG785356

Current Ownership

Information about the current owner(s).

Property History

1816 Ne 19th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 1816 Ne 19th Ave

School Information

Public/private schools serving 1816 Ne 19th Ave

Neighborhood

This property is located in Windom Park, Minneapolis, MN 55418.

Market Trends

Historical market data near 1816 Ne 19th Ave over selected time period.

Nearby Properties on 19th Ave