?
  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
07/28/2023
Sold Price
$252,000$188/ft²

1900 N 25th Ave
Minneapolis, MN 55411

1900 N 25th Ave, Minneapolis, MN 55411 is a 3 bed, 2 bath, 1,344 ft² house built in 1923 on a 0.110 acre lot with 8 construction permits. This house is currently off market, and it was last sold in 2023 for $252,000. The latest TopHap estimate of the house's value is $218,056.

Property Valuations

Latest estimates for 1900 N 25th Ave based on TopHap automated valuation model (AVM).

Permits

1900 N 25th Ave has 8 permit records of total value of $45,000.

Permit History
8
Permits
$45,000
Total Permit Value
May 22, 2014
Description: *IRC1-R/R CODE COMPLIANCE REPAIR AT SFD PER ORDERS BCC1001329 (SZA #02) FINISH ATTIC INCLUDING ADD NEW BATH AND EGRESS WINDOW. CONSTRUCT/REPLACE STOOP AND STEPS ON FRONT OF EXISTING SFD. (sza) MINIMUM LANDING SIZE 36" BY 36" HAND RAIL MUST BE 34" TO 38" ABOVE NOSING OF TREADS (REQUIRED IF 4 OR MORE RISERS) 7 3/4" MAXIMUM RISE ALLOWED AND 10" MINIMUM TREAD DEPTH REQUIRED. THE GREATEST RISER HEIGHT WHITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH. THE GREATEST TREAD DEPTH WHITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN 3/8 INCH. LANDINGS LOCATED MORE THAN 30" ABOVE GRADE SHALL HAVE GUARDS NOT LESS THAN 36" IN HEIGHT. OPEN SIDES OF STAIRS WITH A TOTAL RISE OF MORE THAN 30" ABOVE THE FLOOR OR GRADE BELOW SHALL HAVE GUARDS NOT LESS THAN 34" IN HEIGHT MEASURED VERTICALLY FROM THE NOSING OF THE TREADS. REQUIRED GUARDS SHALL HAVE INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES WHICH DO NOT ALLOW PASSAGE OF A SPHERE 4" OR MORE IN DIAMETER. THE TStatus: finalType: ResidentialApplicant: David P BraunEffective Date: 2014-05-22Permit Number: BLDG41552
January 31, 2014
Description: New circuit breaker panel to replaced fuses. Verify correct wiring 4 new circuitsStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: ST Croix Electric INCApplicant: UnknownFees: $105Effective Date: 2014-01-31Permit Number: ELE1305-01961
January 31, 2014
Description: PLUM FIX Specify the type of fixtures by entering the quantity in the list below: Water Closets_1___ Urinals_____ Bath Tubs__1__ Basins____ Sinks___2__ Wash Trays_____ Showers__1_ Floor Drains____ Extensions__2_ Misc Fixtures_1_ Electric Water Heaters__ _ Other: MISC-DISHWASHER. 1 GAS APPLIANCE code corrections to existing gas water heater Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans Status: finalType: PlumbingApplicant: David P BraunEffective Date: 2014-01-31Permit Number: BLDG502378
January 7, 2014
Description: HVAC W/BNR | Scope of work: HVAC W/BNR - HVAC ALTERATIONS FOR INDIVIDUAL DWELLING UNIT (If multi-unit building, identify the dwelling unit: ____) This permit authorizes the following identified mechanical work to replace and/or modify the existing individual heating/cooling system that serves an individual dwelling unit. Check all that apply. __ Replace boiler including piping alterations __ Replace furnace including duct alterations __ Add or replace heater for space heating _X_ Add or replace air conditioner with furnace including duct alterations**. (INSTALL NEW FURNACE, AIR CONDITIONER, AND DUCTWORK) ITEMS REQUIRED FOR INSPECTION 1. HVAC equipment must be sized according to ACCA manual J or an equivalent method. Calculations to be left next to the new appliances for inspection. Over sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. All documentation relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equStatus: finalType: MechanicalApplicant: David P BraunEffective Date: 2014-01-07Permit Number: BLDG333182
June 11, 2013
Description: HVAC w/bnr - HVAC alterations for individual dwelling unitStatus: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Rvp MechanicalApplicant: Detroit Renovations LlcFees: $129Effective Date: 2013-06-11Permit Number: 4103115
June 11, 2013
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Ray Vinzant PlumbingApplicant: Detroit Renovations LlcFees: $459Effective Date: 2013-06-11Permit Number: 5153871
May 29, 2013
Description: Code compliance repair at single family dwelling per orders bcc1001329 (sza #02)Job Value: $45,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Metro Politan Development IncApplicant: Detroit Renovations LlcFees: $1,468Effective Date: 2013-05-29Permit Number: 3084705
August 20, 1993
Description: Rpl 1 at 100, 000 btu gas-br, residenceStatus: DoneType: Gas burnerSub Type: QmApplicant: Detroit Renovations Llc0Effective Date: 1993-08-20Permit Number: 83089

Current Ownership

Information about the current owner(s).

Property History

1900 N 25th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 1900 N 25th Ave

School Information

Public/private schools serving 1900 N 25th Ave

Neighborhood

This property is located in Jordan, Minneapolis, MN 55411.

Market Trends

Historical market data near 1900 N 25th Ave over selected time period.

Nearby Properties on 25th Ave