?
  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Commercial > Retail
Sold
01/17/2023
Sold Price
$--$--/ft²

20629 Redwood Rd
Castro Valley, CA 94546

20629 Redwood Rd, Castro Valley, CA 94546 is a 1 bath, 42,359 ft² commercial retail property property built in 1969 on a 3.790 acre lot with 68 construction permits. This commercial retail property is currently off market, and it was last sold in 2023.

Permits

20629 Redwood Rd has 68 permit records.

Permit History
68
Permits
September 21, 2022
Description: Commercial tenant improvement for safeway per plans (259 sf): 1) interior renovations to provide a grocery staging area to house a reach in refrigerator and freezer warming unit and shelving. 2) install new parking stall signage to designate six (6) existing grocery pick-up parking stallsStatus: issuedType: Building permitEffective Date: 2022-09-21Permit Number: BLD2022-01389
March 11, 2021
Description: Install 1 - illuminated channel sign and 1 - set of acrylic fco letters non illuminated above retail entrance. (parking lot post monument signs not included)Status: expiredType: Building permitEffective Date: 2021-03-11Permit Number: BLD2020-04053
June 15, 2020
Description: Remodel safeway existing 51713 sf total. Interior scope includes major interior remodel relocated refrigeration cases shelving checkstands and displays restrooms remodel. Existing electrical panels and switchboards. Exterior scope includes updating accessible parking path of travel and signage. **note that signage illuminated on building exterior and starbucks remodel shall be on separate permit**Status: finalType: Building permit buildingEffective Date: 2020-06-15Permit Number: BLD2019-01765
November 22, 2019
Description: For safeway. Replacement of 2 bakery ovens and 1 prooferStatus: approvedType: Simple permitEffective Date: 2019-11-22Permit Number: BLD2019-04191
October 30, 2019
Description: For safeway. Installation of 1 new refrigerator case in retail areaStatus: finalType: Simple permitEffective Date: 2019-10-30Permit Number: BLD2018-03939
October 15, 2019
Description: Removing existing starbucks kiosk inside safeway store installing new 230 sf kiosk in same general area and remodeling the areaStatus: finalType: Building permit buildingEffective Date: 2019-10-15Permit Number: BLD2019-01642
August 1, 2019
Description: Led upgrade on sales floor fornt of bakery front of deli & customer service. Safeway storeStatus: finalType: Building permit buildingEffective Date: 2019-08-01Permit Number: BLD2019-01653
October 25, 2018
Description: Safeway grocery - staging area tenant improvement (300 sf) to house reach in refrigerator reach in freezer and shelving (dug). For safeway 1. Install new air conditioning and condensing units on roof 2. Install shelving refrigerator and freezer in staging area 3. Install new partition wall with bracing to roof framingStatus: completeType: Simple permitEffective Date: 2018-10-25Permit Number: BLD2018-01651
January 4, 2018
Description: Replace refrigerated display cases in the meat and seafood area for safewayStatus: finalType: Building permit buildingEffective Date: 2018-01-04Permit Number: BLD2017-01660
December 26, 2017
Description: Install 2 hussman movable refrigerated cases in the retail area. For safewayStatus: finalType: Building permit buildingEffective Date: 2017-12-26Permit Number: BLD2017-03038
May 19, 2017
Description: Replace 100 gallon water heater like for likeStatus: finalType: Building permit buildingEffective Date: 2017-05-19Permit Number: BLD2017-01251
October 8, 2015
Description: Addition 1 new circuit for turkey trailer in backroom of store @ exterior wallStatus: PERMIT ISSUEDType: BuildingBusiness Name: H A BOWEN ELECTRIC INC0Effective Date: 2015-10-08Permit Number: BLD2015-03094
September 17, 2015
Description: For safeway to enclose and remodel the existing produce prep area (310 sf) in the existing warehouse area at the southwest corner of the building installing walls sinks counters fixtures lights etc per plans also to remove an existing fixture and install a new mobile self-service refrigerated case (self contained)Status: finalType: Building permit buildingEffective Date: 2015-09-17Permit Number: BLD2015-01611
October 15, 2014
Description: To remodel a safeway store per plan: 1) replace soup bar installing new floor sink plumbing wiring 2) replace s/c produce case using existing electrical 3) replace dry shelves in the produce areaStatus: finalType: Simple permitEffective Date: 2014-10-15Permit Number: BLD2014-01414
January 16, 2014
Description: Addition 30a 208v 1 phase outlet (new circuit)for portable U.P.S. In the pharmacy areaStatus: finalType: Building permit buildingEffective Date: 2014-01-16Permit Number: BLD2013-00534
July 23, 2013
Description: Request to allow installation of one illuminated exterior sign (and one non-illuminated interior wall sign)Status: REVIEW COMPLETEType: BuildingBusiness Name: ASSOCIATED SIGN CO // BENN, WILLIAMEffective Date: 2013-07-23Permit Number: PLN2010-00075
January 31, 2013
Description: Addition dedicated circuit for sales floor kiosk (for personal electronics rollout). For safeway storesStatus: finalType: Building permit buildingEffective Date: 2013-01-31Permit Number: BLD2012-02072
November 29, 2012
Description: Addition second consultation room in pharmacy (48 sq. Ft.) within footprint. Demolish existing pill bay addition store front material. Install one light and switch. For safeway storeStatus: finalType: Building permit buildingEffective Date: 2012-11-29Permit Number: BLD2012-01121
June 1, 2012
Description: Install a relocated floor sink for a replacement refrigerated dairy caseStatus: finalType: Building permit buildingEffective Date: 2012-06-01Permit Number: BLD2012-00733
May 23, 2012
Description: For safeway stores. Disconnect existing refrigerated case and reconnect new oneStatus: FINALEDType: BuildingBusiness Name: H A BOWEN ELECTRICEffective Date: 2012-05-23Permit Number: BLD2012-00863
April 13, 2012
Description: Supplemental permit to bld2011-02668. Install an additional safeway pharmacy sign (c1 and c2) - new illiminated sign per approved plans. For safewayStatus: finalType: Building permit buildingEffective Date: 2012-04-13Permit Number: BLD2012-00033
April 13, 2012
Description: To install 7 new illiminated signs per approved plans. Safeway us bank starbucks coffee signature cafe pharmacy. For safewayStatus: finalType: Building permit buildingEffective Date: 2012-04-13Permit Number: BLD2011-02668
March 22, 2012
Description: New trash enclosure (at rear of building) for safewayStatus: finalType: Building permit buildingEffective Date: 2012-03-22Permit Number: BLD2011-01279
February 15, 2012
Description: Rewire 1 existing electrical circuit for health station ( blood presure machine)Status: finalType: Building permit buildingEffective Date: 2012-02-15Permit Number: BLD2012-00132
February 9, 2012
Description: Install 3 new windows in cmu wall for interior seating area @ starbucks coffee shop safeway per approved plans and calculationsStatus: finalType: Building permit buildingEffective Date: 2012-02-09Permit Number: BLD2011-02584
December 21, 2011
Description: Remove existing pharmacy storage room coffee storage room hippa storage room. Enlarge pharmacy waiting room refurbish toilet room building new pharmacy storage room new consulting office replace select pharmacy fixtures and equipment electrical mechanical and plumbing improvements to support new improvementsStatus: finalType: Building permit buildingEffective Date: 2011-12-21Permit Number: BLD2011-00513
March 15, 2011
Description: Relocate two existing checkstands (swap location). Addition 2 new and re-configure (4) existing self-checkout stands. Modify existing electrical circuits as needed. For safewayStatus: EXPIREDType: BuildingBusiness Name: H A BOWEN ELECTRICEffective Date: 2011-03-15Permit Number: BLD2011-00235
October 5, 2010
Description: Install one new circuit for a printerStatus: completeType: BuildingBusiness Name: KW CONSTRUCTION0Effective Date: 2010-10-05Permit Number: BLD2010-02110
August 2, 2010
Description: Minor tenant improvement. Work to existing bank facility inside safeway store. (re-branding) - replace atm machine change out existing doors reface casework. No change to partion lay-out. New emergency lighting only. [extrior signs under separate permit]Status: finalType: Building permit buildingEffective Date: 2010-08-02Permit Number: BLD2010-01117
July 23, 2010
Description: Installation of illuminated sign on the exterior of the building for us bankStatus: completeType: BuildingBusiness Name: ASSOCIATED SIGN COMPANY0Effective Date: 2010-07-23Permit Number: BLD2010-01489
April 2, 2010
Description: Remove existing chicken case in deli and install new larger chicken case. For safeway storesStatus: finalType: Building permit buildingEffective Date: 2010-04-02Permit Number: BLD2010-00405
November 18, 2009
Description: Install 1 - 50 amp outlet in receiving/warehouse area for safeway incStatus: finalType: Building permit buildingEffective Date: 2009-11-18Permit Number: BLD2009-02283
October 2, 2009
Description: Reroof. Tear off capsheet built-up roof. Mechanically attach 1/4 dens deck insulation. Then mechanically attach w/screws 60 msl carlisle tpo single roof membrane. Class a. Icc evaluation report 2403. Approx. 410 squares. For safewayStatus: finalType: Building permit buildingEffective Date: 2009-10-02Permit Number: BLD2009-01665
June 2, 2009
Description: To allow modification to an approved sdr with the addition of windows at the front of the building & utilizing 7 parking stalls for truck parking 10 weeks per yearStatus: DRPType: BuildingBusiness Name: NADEL ARCHITECTSEffective Date: 2009-06-02Permit Number: PLN_MS-1752E
September 4, 2008
Description: Extend existing circuit to install video monitor in pharmacy gondolaStatus: finalType: Building permit buildingEffective Date: 2008-09-04Permit Number: BLD2008-01921
August 28, 2008
Status: issuedType: BuildingBusiness Name: COBURN RALPH G TRUSTEE ETAL0Effective Date: 2008-08-28Permit Number: BLD2008-01920
August 15, 2008
Description: Altering 1 circuit. Relocating existing electrical outlet in aisle 10 approx. 6 down aisle (circuit #r1-9). For safeway storesStatus: finalType: Building permit buildingEffective Date: 2008-08-15Permit Number: BLD2008-01494
July 16, 2008
Description: For safeway stores. Water manifold for future water filter. Reduced pressure backflow backflow vent drain pressure reducing valve 1/2 type l copper 20 max. 1/2 cpvc extension pipe for filter hand spray. Work located inside store nest to vegetable rinse sink in food storage area at back area of storeStatus: finalType: Building permit buildingEffective Date: 2008-07-16Permit Number: BLD2008-01558
March 3, 2008
Description: 1 new circuit for 2 interior security outletsStatus: FINALEDType: BuildingBusiness Name: H A BOWEN ELECTRICEffective Date: 2008-03-03Permit Number: BLD2008-00412
November 15, 2007
Description: Interior tenant improvement to existing safeway store. - includes relocation of starbucks kiosk reconfiguration of deli new pizza oven with listed hoodStatus: finalType: Building permit buildingEffective Date: 2007-11-15Permit Number: BLD2007-01420
November 5, 2007
Description: Replace two evaporative coolers/furnaces with the same current models (roof mounted). For safeway storesStatus: finalType: Building permit buildingEffective Date: 2007-11-05Permit Number: BLD2007-02651
October 15, 2007
Description: Misc. Exterior and facade work to safeway store - includes - new exterior seating cart storage relocate trash compactor and enlarge existing enclosure re-stripe parking lot canopy lighting and building mounted signageStatus: filedType: Building permit buildingEffective Date: 2007-10-15Permit Number: BLD2007-03005
January 31, 2006
Description: Remove bbq warmer and dump table and replace it with a soap bar table and thermalizer ( interior tenant improvement. Only)Status: finalType: Building permit buildingEffective Date: 2006-01-31Permit Number: BLD2006-00243
December 23, 2005
Description: Install new circuit for outlet in deli @ existing safeway grocery storeStatus: finalType: Building permit buildingEffective Date: 2005-12-23Permit Number: BLD2005-02090
March 31, 2005
Description: Rewire 1 existing circuit for bakery cabinet lightingStatus: finalType: Building permit buildingEffective Date: 2005-03-31Permit Number: BLD2005-00942
November 1, 2004
Description: Renewal permit covering bld2002-01545. Install new 6 elect wall signs - safeway food & drug safeway 3 logos starbucks coffe and fremont bankStatus: completeType: Simple permitEffective Date: 2004-11-01Permit Number: BLD2003-01768
June 2, 2004
Description: Addition fremont bank to the interior of safewayStatus: expiredType: Simple permitEffective Date: 2004-06-02Permit Number: BLD2002-04354
November 13, 2003
Description: Remodel and expansion to the existing safeway. Demolish 6200sqft. Addition 10, 262sqft compleat interior remodelStatus: finalType: Simple permitEffective Date: 2003-11-13Permit Number: BLD2002-01895
June 5, 2003
Description: Install new 6 elect wall signs - safeway food & drug safeway 3 logos starbucks coffe and fremont bankStatus: completeType: Simple permitEffective Date: 2003-06-05Permit Number: BLD2002-01545
October 16, 2002
Description: Installation of 2 mobile units one for pharmacy and one for customer toilets.8x40 & 12x36Status: completeType: Simple permitEffective Date: 2002-10-16Permit Number: BLD2002-03239
June 12, 2002
Description: Plans check***remodel and expansion to the existing safeway. Demolish 6200sqft. Addition 10, 262sqft compleat interior remodelStatus: completeType: Simple permitEffective Date: 2002-06-12Permit Number: BLD2001-04302
January 7, 1999
Description: Install signStatus: finalType: Simple permitEffective Date: 1999-01-07Permit Number: BLD1998-03348
September 7, 1994
Description: Inst. Illumin. Sign - zoning: cvcbd-sp-7Status: completeType: Building permit buildingEffective Date: 1994-09-07Permit Number: BLD1993-01801
October 28, 1991
Description: Install single face signStatus: completeType: Building permit buildingEffective Date: 1991-10-28Permit Number: BLD1991-00800
October 28, 1991
Description: Replace existing sign - zoning: cvbd-aStatus: completeType: Building permit buildingEffective Date: 1991-10-28Permit Number: BLD1989-02643
October 28, 1991
Description: Electrical four neon signs safewayStatus: completeType: Building permit buildingEffective Date: 1991-10-28Permit Number: BLD1989-01682
December 10, 1990
Description: Renewal of permit #90-1603Status: completeType: Building permit buildingEffective Date: 1990-12-10Permit Number: BLD1990-02879
October 26, 1990
Description: Repair commer. Building. - zoning: cvcbd-grp.aStatus: completeType: Building permit buildingEffective Date: 1990-10-26Permit Number: BLD1990-01603
October 26, 1990
Description: Remodel store - zoning: gp aStatus: finalType: Building permit buildingEffective Date: 1990-10-26Permit Number: BLD1989-00779
March 28, 1990
Description: New bank within safeway storeStatus: finalType: Building permit buildingEffective Date: 1990-03-28Permit Number: BLD1989-03603
January 14, 1988
Description: Repair leaks in gas line single family dwellingStatus: finalType: Building permit buildingEffective Date: 1988-01-14Permit Number: BLD1988-00075
May 16, 1986
Description: Alteration to store commercial - zoning: eac/jyStatus: completeType: Building permit buildingEffective Date: 1986-05-16Permit Number: BLD1986-05277
January 1, 1900
Description: To allow renovation of the safeway store with new paint colors signage new outdoor display & seating new windows for the starbuck's portion of the store and to designate an area for seasonal truck parking. (pln2010-00186 young)Status: NEW PERMIT OPENEDType: BuildingBusiness Name: COBURN RALPH G TRUSTEE ETALEffective Date: 1900-01-01Permit Number: SAM2010-00103
January 1, 1900
Description: Allow modification of expansion of the existing supermarketStatus: NEW PERMIT OPENEDType: BuildingBusiness Name: COBURN RALPH G TRUSTEE ETALEffective Date: 1900-01-01Permit Number: SAM2002-00351
January 1, 1900
Status: DRPType: BuildingBusiness Name: MCG ARCHITECTUREEffective Date: 1900-01-01Permit Number: PLN_MS-1752C
January 1, 1900
Description: * to allow temporary use of a seasonal (safeway) turkey truckStatus: CAType: BuildingBusiness Name: SAFEWAY, INC // JOHNSON, DAVE //JOHNSON LYMAN ARCHITECTSEffective Date: 1900-01-01Permit Number: PLN2010-00197
January 1, 1900
Description: To allow renovation of the safeway store with new paint colors signage new outdoor display & seating; new windows for starbucks portion of store and to designate an area for seasonal truck parkingStatus: REVIEW COMPLETEType: BuildingBusiness Name: SAFEWAY, INC // JOHNSON, DAVE - JOHNSON LYMAN ARCHITECTSEffective Date: 1900-01-01Permit Number: PLN2010-00186
January 1, 1900
Description: Zoning verification letterStatus: REVIEW COMPLETEType: BuildingBusiness Name: COBURN RALPH G TRUSTEE ETALEffective Date: 1900-01-01Permit Number: PLN2014-00169

Current Ownership

Information about the current owner(s).

Property History

20629 Redwood Rd has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 20629 Redwood Rd

School Information

Public/private schools serving 20629 Redwood Rd

Neighborhood

This property is located in Castro Valley, Castro Valley, CA 94546.

Market Trends

Historical market data near 20629 Redwood Rd over selected time period.

Nearby Properties on Redwood Rd