800 Ne 19th Ave has 33 permit records of total value of $113,545.

Permit History
33
Permits
$113,545
Total Permit Value
May 26, 2016
Description: *irc1-add partial rear 2nd floor addition over existing kitchen area of a single family house. Aaj#2. Demolition: - partial demolition to allow for new addition and interior renovation work to be done. Basement/crawl space floor remodel: - install new 2 x 8 floor joists @ 12 O.C. Above existing crawl space as noted on basement floor plan. - repair existing foundation wall as noted on basement floor plan. - install crawl space access per code requirement. ***verify crawl space ventilation per irc section r408.1. Main floor remodel: - install new partition walls to enclose new 6'0 x 8'6 bathroom addition on main floor. - install bathroom fixtures per code requirement. - replace existing window in bedroom #1 with two new windows and install header. Min. 2 - 2 x 10 header. 2nd floor addition and remodel: - install new studs and partiton walls to enclose new 16'0 x 19'5 addition on rear elevation of existing 2nd floor to be used as bedroom #4 with two closet and hallway. - also install new Status: finalType: ResidentialApplicant: Jeaneth BrubakkenEffective Date: 2016-05-26Permit Number: BLDG46422
April 5, 2016
Description: Plumbingfix rough in of drain waste vent and water lines to kitchen two bathrooms and washer box _______________________________________ specify the type of fixtures by entering the quantity in the list below: water closets____ urinals_____ bathroom tubs____ basins____ sinks_____ wash trays_____ showers_____ floor drains____ extensions_____ misc fixtures____ electric water heaters_____ other: specify below properly plug the unused plumbingopenings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbingmaterials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbingcontractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional informatioStatus: finalType: plumbingApplicant: Jeaneth BrubakkenEffective Date: 2016-04-05Permit Number: BLDG536105
March 31, 2016
Project Name: Jeaneth HouseStatus: finalType: Ele new 1 or 2 familySub Type: Residential newApplicant: Jeaneth BrubakkenFees: $206Effective Date: 2016-03-31Permit Number: ELE1509-06260
December 4, 2015
Description: *irc1-r/r add13'-3 x 6'-5 deck atthe rear od single family dwelling (maa #02) separate permits are required for electrical plumbingand heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into the interior for insStatus: finalType: ResidentialApplicant: Jeaneth BrubakkenEffective Date: 2015-12-04Permit Number: BLDG50115
November 3, 2015
Description: *irc1-r/r jack up house and repair foundation as per engineer's inspection and advice (maa#02) relocate first floor bathroom addition 2nd floor bathroom. *******submit engineer's report/letter to building inspector and to our office********* separate permits are required for electrical plumbingand heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could providStatus: finalType: ResidentialApplicant: Jeaneth BrubakkenEffective Date: 2015-11-03Permit Number: BLDG41769
November 3, 2015
Description: *irc1-r/r demolish to single family dwelling for investigative purposes for foundation and structure. No plan. (dmh) separate permits are required for electrical plumbingand heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not Status: finalType: ResidentialApplicant: Jeaneth BrubakkenEffective Date: 2015-11-03Permit Number: BLDG48907
October 16, 2015
Description: Add13'-3 x 6'-5 deck atthe rear od single family dwelling (maa #02)Job Value: $4,800Status: OpenType: RemodelingSub Type: BireBusiness Name: Jeaneth BrubakkenApplicant: Jeaneth BrubakkenFees: $265Effective Date: 2015-10-16Permit Number: 3101099
October 9, 2015
Description: | scope of work: replace furnace and air conditioning _______________________________________ HVAC work and replacement of boiler/furnace identify number of each of the existing individual heating/cooling system being replaced that serves an individual dwelling unit. Indicate the number of systems that apply: __ replace boiler plus incidental piping __ replace furnace only with or without a/c** - plenum included (no duct work beyond plenum) __ addition or replace space heating unit required for inspection 1. HVAC equipment must be sized to acca manual j or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the proper minneapolis installer competency card employed by the minneapStatus: finalType: MechanicalApplicant: Jeaneth BrubakkenEffective Date: 2015-10-09Permit Number: BLDG351674
October 9, 2015
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: New ductwork, furnace 60,000 BTU's 2 bath fans Heating load calculation forms for furnaces and boilers installed in single family homes or duplexes are required to be left at the job site along with the homeowner package of information that includes the design, testing, and installation instructions. Contractors should be using manual J residential load calculations hand written or software designed. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which is equipped with central air condStatus: completeType: MechanicalBusiness Name: Larson Plumbing & Heating IncApplicant: Jeaneth BrubakkenEffective Date: 2015-10-09Permit Number: BLDG329849
October 6, 2015
Project Name: BrobakkenDescription: Replace furnace and air conditioningStatus: finalType: Ele new 1 or 2 familyBusiness Name: Home Energy Center INCApplicant: Jeaneth BrobakkenFees: $36Effective Date: 2015-10-06Permit Number: ELE1508-00441
August 28, 2015
Description: Rough in of drain waste vent and water lines to kitchen two bathrooms and washer boxStatus: OpenType: plumbingSub Type: BtpaBusiness Name: Norblom PlumbingApplicant: Jeaneth BrubakkenFees: $319Effective Date: 2015-08-28Permit Number: 5183233
July 23, 2015
Description: Replace furnace and air conditioningStatus: OpenType: HVAC alterationsSub Type: BtmbBusiness Name: Home Energy CenterApplicant: Jeaneth BrubakkenFees: $128Effective Date: 2015-07-23Permit Number: 4113856
August 13, 2014
Description: Partial rear 2nd floor addition over existing kitchen area of a single family house. Aaj#2Job Value: $55,694Status: OpenType: RemodelingSub Type: BireBusiness Name: Jeaneth BrubakkenApplicant: Jeaneth BrubakkenFees: $1,635Effective Date: 2014-08-13Permit Number: 3092933
June 20, 2013
Description: New ductwork furnace 60, 000 btu's 2 bathroom fansStatus: OpenType: MechanicalSub Type: BtmaBusiness Name: Larson Plumbing & HeatingApplicant: Jeaneth BrubakkenFees: $178Effective Date: 2013-06-20Permit Number: 4109874
June 19, 2013
Description: Jack up house and repair foundation as per engineer's inspection and advice (maa#02)Job Value: $40,000Status: OpenType: RemodelingSub Type: BireBusiness Name: Looking Glass Properties, LlcApplicant: Jeaneth BrubakkenFees: $1,253Effective Date: 2013-06-19Permit Number: 3085134
April 22, 2013
Description: Specify the type of fixtures by entering the quantity in the list below:Status: OpenType: plumbingSub Type: BtpaBusiness Name: Weld & Sons PlumbingApplicant: Jeaneth BrubakkenFees: $391Effective Date: 2013-04-22Permit Number: 5152425
April 22, 2013
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets__2__ urinals_____ bathroom tubs__1__ basins_2___ sinks__1___ wash trays_____ showers__1___ floor drains____ extensions_____ misc fixtures__3__ electric water heaters_____ other: specify below----------------dishwasher washer box water heater------------------------------- properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/Status: completeType: plumbingBusiness Name: Weld & Sons Plumbing IncApplicant: Jeaneth BrubakkenEffective Date: 2013-04-22Permit Number: BLDG508330
April 4, 2013
Description: Service reconnectionStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Apollo Electric Services INCApplicant: Cpm LLCFees: $40Effective Date: 2013-04-04Permit Number: ELE1304-01331
January 18, 2013
Description: Demolish to single family dwelling for investigative purposes for foundation and structure. No plan. (dmh)Job Value: $500Status: OpenType: RemodelingSub Type: BireBusiness Name: Looking Glass Properties, LlcApplicant: Jeaneth BrubakkenFees: $77Effective Date: 2013-01-18Permit Number: 3082693
July 31, 2002
Description: Exterior tearoff and reroof houseStatus: finalType: ResidentialApplicant: Jeaneth BrubakkenEffective Date: 2002-07-31Permit Number: BLDG197881
April 23, 2002
Description: Mechanical mechanical | scope of work: gas furnace only @ 80mbh patty morris mechanical | scope of work: gas furnace only @ 80mbh patty morris mechanical | scope of work: gas furnace only @ 80mbh patty morris mechanical | scope of work: gas furnace only @ 80mbh patty morrisStatus: finalType: MechanicalApplicant: Jeaneth BrubakkenEffective Date: 2002-04-23Permit Number: BLDG381644
April 2, 2002
Description: plumbingredo all plumbingper tih - 1-wc 1-bt 1-bn 1-sk 1-stand pipe 1-ew 1-gd 1-grStatus: finalType: PlumbingApplicant: Jeaneth BrubakkenEffective Date: 2002-04-02Permit Number: BLDG590275
March 12, 2002
Description: Tearoff and reroof houseJob Value: $1,600Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Patty Morris/ownerApplicant: Jeaneth BrubakkenFees: $58Effective Date: 2002-03-12Permit Number: 1042480
December 10, 2001
Description: Redo all plumbing per tih - 1-wc 1-bt 1-bn 1-sk 1-stand pipe 1-ew 1-gd 1-grStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Barnes Plumbing Co, IncApplicant: Jeaneth BrubakkenFees: $225Effective Date: 2001-12-10Permit Number: 5026948
November 8, 2001
Description: Wire furnaceJob Value: $1Status: DoneType: ElectricalSub Type: BteaBusiness Name: Rts ElectricApplicant: Jeaneth BrubakkenFees: $42Effective Date: 2001-11-08Permit Number: 1037940
October 31, 2001
Description: Gas furnace only @ 80mbhStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Allied Fireside IncApplicant: Jeaneth BrubakkenFees: $42Effective Date: 2001-10-31Permit Number: 4023993
October 30, 2001
Description: 1 - 100amp service 12 circuitsJob Value: $5,000Status: DoneType: ElectricalSub Type: BteaBusiness Name: D & L ElectricApplicant: Jeaneth BrubakkenFees: $147Effective Date: 2001-10-30Permit Number: 1037562
October 28, 2001
Description: Install 1 80, 000 btu gas br for furnaceStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Allied Fireside IncApplicant: Jeaneth BrubakkenFees: $42Effective Date: 2001-10-28Permit Number: 4023859
October 11, 2001
Description: Install new furnace with ductworkJob Value: $5,000Status: DoneType: MechanicalSub Type: BtmaBusiness Name: Silvernail Entr, LtdApplicant: Jeaneth BrubakkenFees: $78Effective Date: 2001-10-11Permit Number: 4023277
March 31, 1998
Description: Ins 1@40 gas addition space heater m=jhJob Value: $950Status: DoneType: Gas burnerSub Type: QmApplicant: Jeaneth Brubakken0Effective Date: 1998-03-31Permit Number: 114651
January 1, 1900
Description: Mechanical mechanical | scope of work: install 1 80, 000 btu gas br for furnace mechanical | scope of work: install 1 80, 000 btu gas br for furnace mechanical | scope of work: install 1 80, 000 btu gas br for furnace mechanical | scope of work: install 1 80, 000 btu gas br for furnaceStatus: completeType: MechanicalBusiness Name: Allied Fireside INCApplicant: Jeaneth BrubakkenEffective Date: 1900-01-01Permit Number: BLDG369214
January 1, 1900
Description: Meter move q2 - 2020 batch #3Status: completeType: plumbingBusiness Name: Center Point Energy Resource CorpApplicant: Jeaneth BrubakkenFees: $85Effective Date: 1900-01-01Permit Number: BLDG867050
January 1, 1900
Description: Mechanical mechanical | warm air heating systems | scope of work: install new furnace with ductwork patty morris mechanical | scope of work: install new furnace with ductwork patty morris mechanical | scope of work: install new furnace with ductwork patty morris mechanical | scope of work: install new furnace with ductwork patty morrisStatus: completeType: MechanicalBusiness Name: Silvernail Entr LTDApplicant: Jeaneth BrubakkenEffective Date: 1900-01-01Permit Number: BLDG380942

Current Ownership

Information about the current owner(s).

Property History

800 Ne 19th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 800 Ne 19th Ave

School Information

Public/private schools serving 800 Ne 19th Ave

Neighborhood

This property is located in Logan Park, Minneapolis, MN 55418.

Market Trends

Historical market data near 800 Ne 19th Ave over selected time period.

Nearby Properties on 19th Ave