  • Chat with Us
  • Submit Feedback
  • TopHap Academy
  • What's New?
Residential > House
Sold
11/19/2014
Sold Price
$239,000$107/ft²

809 Ne 27th Ave
Minneapolis, MN 55418

809 Ne 27th Ave, Minneapolis, MN 55418 is a 4 bed, 2 bath, 2,228 ft² house built in 1900 on a 0.170 acre lot with 19 construction permits. This house is currently off market, and it was last sold in 2014 for $239,000. The latest TopHap estimate of the house's value is $344,031.

Property Valuations

Latest estimates for 809 Ne 27th Ave based on TopHap automated valuation model (AVM).

Permits

809 Ne 27th Ave has 19 permit records of total value of $69,400.

Permit History
19
Permits
$69,400
Total Permit Value
October 27, 2020
Description: Reconnect furnaceStatus: expiredType: Electrical permitSub Type: One-family dwellingApplicant: Isamar PizarroFees: $36Effective Date: 2020-10-27Permit Number: ELE2010-09664
July 16, 2014
Description: *IRC1-R/R PERMIT FOR WORK ALREADY STARTED. INTERIOR REHAB TO 1ST & 2ND FLOORS OF SFD. (DMH#2) GUT EXISTINGS FINISHES TO FRAMING. INSTALL F.G INSULATION AND VAPOR BARRIER AT EXTERIOR WALL CONDITIONS. INSTALL CEMENT BACKER BOARD FOR CERAMIC TILE AT TUB/SHOWER LOCATIONS AND DRYWALL FINISHES ELSEWHERE. NO NEW FRAMING BEING DONE. NO BASEMENT WORK. REPLACE 7 WINDOWS IN EXISTING OPENING. TEAR OFF AND REROOF. CONSTRUCT 20'X11' TREATED WOOD DECK AT REAR YARD WITH 2X8 JOISTS, (2) 2X8 BEAMS, GUARDRAIL, STAIRS, HANDRAIL, TREATED WOOD POSTS AND 4 FOOTING LOCATIONS. CONSTRUCT 21 BY 26 DETACHED GARAGE. THIS PERMIT DOES NOT APPROVE A BASMENT BEDROOM, EXISTING FINISHES BUILT WITHOUT A PERMIT, ADDITIONAL DWELLING UNIT OR WORK OTHER THAN DESCRIBED. Grippable handrail height 34"-38" above nose of tread required at 4 or more risers. 7 3/4" maximum rise, 10" minimum tread allowed at stairs. 36" minimum Guardrail height and less than 4" space required when 30" or more above grade. Frost footing depth minimumStatus: finalType: ResidentialApplicant: Leovarda Munoz PizarroEffective Date: 2014-07-16Permit Number: BLDG77417
June 5, 2014
Description: PLUM FIX INSTALLING 1 GAS WATER HEATER, 1 GAS RANGE, 1 GAS DRYER AND THE FOLLOWING Specify the type of fixtures by entering the quantity in the list below: Water Closets__2__ Urinals_____ Bath Tubs__2__ Basins__2__ Sinks__1___ Wash Trays__1___ Showers_____ Floor Drains____ Extensions_____ Misc Fixtures____ Electric Water Heaters_____ Other: Specify below Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_0Status: finalType: PlumbingApplicant: Leovarda Munoz PizarroEffective Date: 2014-06-05Permit Number: BLDG507573
February 11, 2014
Description: Whole house re-habStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Sunshine Electric LLCApplicant: Olmedo AdvocadoFees: $140Effective Date: 2014-02-11Permit Number: ELE1308-03024
January 30, 2014
Description: HVAC-LVL3 | Scope of work: HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** Identify number of each of the existing individual heating/cooling system being replaced, that serves an individual dwelling unit. Indicate the number of systems that apply: _1_Remove existing system and install new (boiler or forced air system) __Install a new system to serve an existing non-conditioned space or addition REQUIRED FOR INSPECTION 1. HVAC equipment must be sized to ACCA manual J or an equivalent method. Heat loss calculations to be left next to appliances for inspection. Over-sizing of heating equipment must not exceed 43% and cooling equipment must not exceed 21%. 2. Documents relative to maintenance and startup testing (orsat) shall be affixed to the mechanical equipment. 3. All work done under this permit must be completed by a person with the proper Minneapolis installer competency card employed by the Minneapolis licensed permit applicant. 4. Existing mechanical code violations to be corrected at Status: completeType: MechanicalBusiness Name: Heating & Cooling Design IncApplicant: Leovarda Munoz PizarroEffective Date: 2014-01-30Permit Number: BLDG335721
November 12, 2013
Description: Permit for work already started. Interior rehab to 1st & 2nd floors of single family dwelling. (dmh#2)Job Value: $55,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Olmedo AlvaradoApplicant: L & I Munoz PizarroFees: $2,250Effective Date: 2013-11-12Permit Number: 3088327
October 16, 2013
Description: *IRC1-R/R TEAR OFF AND REROOF HOUSE. REPLACE 8 WINDOWS IN EXISTING OPENINGS. NO PLANS. (DMH) DISCUSSED TEMPERED WINDOW LOCATIONS AND EGRESS WINDOW REQUIREMENTS FOR RENTAL UNITS WITH APPLICANT. WINDOW REPLACEMENTS IN RENTAL PROPERTIES OR STATE LICENSED FACILITIES MUST MEET THE CURRENT REQUIREMENT FOR EGRESS WINDOWS PER MNSBC CHAPTER 1309 SECTION R310.1.5 SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior Status: finalType: ResidentialApplicant: Leovarda Munoz PizarroEffective Date: 2013-10-16Permit Number: BLDG131281
September 24, 2013
Description: Vinyl siding on all sides of houseStatus: DoneType: Building over the counterSub Type: BotcBusiness Name: Olmedo AlvaradoApplicant: L & I Munoz PizarroFees: $157Effective Date: 2013-09-24Permit Number: 1111832
August 6, 2013
Description: HVAC work and entire system replacementStatus: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Heating & Cooling DesignApplicant: L & I Munoz PizarroFees: $207Effective Date: 2013-08-06Permit Number: 4103914
August 2, 2013
Description: Installing 1 gas water heater 1 gas range 1 gas dryer and the followingStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Frank Motzko PlumbingApplicant: L & I Munoz PizarroFees: $519Effective Date: 2013-08-02Permit Number: 5155417
July 26, 2011
Description: Tear off and reroof house. Replace 8 windows in existing openings. No plans. (dmh)Job Value: $8,000Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Alexander DehzadApplicant: L & I Munoz PizarroFees: $205Effective Date: 2011-07-26Permit Number: 1095776
May 9, 2011
Description: Repairs to walls in 2 bedrooms and kitchen reflash chimney. LbfJob Value: $500Status: DoneType: RemodelingSub Type: BireBusiness Name: Alexander DehzadApplicant: L & I Munoz PizarroFees: $74Effective Date: 2011-05-09Permit Number: 3071101
January 24, 2007
Description: plumbing install 1 electric water heaterStatus: finalType: plumbingApplicant: Leovarda Munoz PizarroEffective Date: 2007-01-24Permit Number: BLDG401912
December 11, 2006
Description: MECH MECH | WARM AIR HEATING SYSTEMS | Scope of work: INSTALL GOODMAN BRAND, 70 MBH FURNACE. HEAT LOSS SHEET(S) ATTACHED TO APPLICATION FILED IN INPSECTIONS OFFICE. LAWRENCE LEMKE MECH | Scope of work: INSTALL GOODMAN BRAND, 70 MBH FURNACE. HEAT LOSS SHEET(S) ATTACHED TO APPLICATION FILED IN INPSECTIONS OFFICE. LAWRENCE LEMKE MECH | Scope of work: INSTALL GOODMAN BRAND, 70 MBH FURNACE. HEAT LOSS SHEET(S) ATTACHED TO APPLICATION FILED IN INPSECTIONS OFFICE. LAWRENCE LEMKE MECH | Scope of work: INSTALL GOODMAN BRAND, 70 MBH FURNACE. HEAT LOSS SHEET(S) ATTACHED TO APPLICATION FILED IN INPSECTIONS OFFICE. LAWRENCE LEMKEMechanical mechanical | warm air heating systems | scope of work: install goodman brand 70 mbh furnace. Heat loss sheet(s) attached to application filed in inpsections office. Lawrence lemke mechanical | scope of work: install goodman brand 70 mbh furnace. Heat loss sheet(s) attached to application filed in inpsections office. Lawrence lemke mechanical | scope of work: instaStatus: completeType: Mechanical; Mechanical permitSub Type: MechanicalBusiness Name: Centraire Htg & A / C Inc; Centraire Htg and A/C IncApplicant: Leovarda Munoz Pizarro; I Munoz Pizarro0Effective Date: 2006-12-11Permit Number: BLDG312154
December 11, 2006
Description: Install goodman brand 70 mbh furnace. Heat loss sheet(s) attached to application filed in inpsections officeStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Centraire Htg & A/c IncApplicant: L & I Munoz PizarroFees: $89Effective Date: 2006-12-11Permit Number: 4065819
December 12, 2002
Description: Install 1 electric water heaterJob Value: $400Status: DoneType: plumbingSub Type: BtpaBusiness Name: Norblom PlumbingApplicant: L & I Munoz PizarroFees: $36Effective Date: 2002-12-12Permit Number: 5037804
January 1, 1900
Description: Install replace daikin furnaceStatus: completeType: MechanicalBusiness Name: Centerpoint EnergyApplicant: Leovarda Munoz PizarroFees: $133Effective Date: 1900-01-01Permit Number: BLDG856512
January 1, 1900
Description: *irc1-r/r repairs to walls in 2 bedrooms and kitchen reflash chimney. Lbf separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnection without the removal of interior finishes. 2. Work on the exterior which does not require entry into the interior for inspectJob Value: $500Status: completeType: ResidentialBusiness Name: Alexander DehzadApplicant: Leovarda Munoz PizarroEffective Date: 1900-01-01Permit Number: BLDG72073
January 1, 1900
Description: Siding vinyl siding on all sides of house repair/replace existing siding w/o altering structural elements. M.c.o. 89.165 completion of work - all work for altering repairing or remodeling the exterior portion of a single-family dwelling or two-family dwelling including an attached or detached garage shall be completed within one 1) year from the date of issuance of the building permit. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.dli.mn.gov/ccld/pdf/bc_websmoke_co_06_07.pdfJob Value: $5,000Status: completeType: ResidentialBusiness Name: Olmedo AlvaradoApplicant: Leovarda Munoz PizarroEffective Date: 1900-01-01Permit Number: BLDG144658

Current Ownership

Information about the current owner(s).

Property History

809 Ne 27th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 809 Ne 27th Ave

School Information

Public/private schools serving 809 Ne 27th Ave

Neighborhood

This property is located in Columbia Park, Minneapolis, MN 55418.

Market Trends

Historical market data near 809 Ne 27th Ave over selected time period.

Nearby Properties on 27th Ave