876 Se 18th Ave
Minneapolis, MN 55414

876 Se 18th Ave, Minneapolis, MN 55414 is a 3 bed, 2 bath, 1,420 ft² house built in 1910 on a 0.120 acre lot with 19 construction permits. This house is currently off market. The latest TopHap estimate of the house's value is $311,290.

Property Valuations

Latest estimates for 876 Se 18th Ave based on TopHap automated valuation model (AVM).

Permits

876 Se 18th Ave has 19 permit records of total value of $40,029.

Permit History
19
Permits
$40,029
Total Permit Value
March 26, 2014
Project Name: Natalie RecitutiDescription: Radon fanStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Oaks Electric COApplicant: Natalie ReciputiFees: $40Effective Date: 2014-03-26Permit Number: ELE1402-00132
February 4, 2014
Description: | scope of work: miscellaneous HVAC work (no burners) identify mechanical work of the existing individual heating/cooling system that serves an individual dwelling unit. Indicate the number of systems that apply: __ radiation piping for space heating* __ supplies and returns (4 openings or less) _x_ fresh air intake air cleaner humidifier venting fans gas piping (heating systems only) radon mitigation and other accessories __ air conditioner add-on or replacement** __ solid fuel heating devices (wood pellets etc.) radon mitigation required for inspection 1. All work done under this permit must be completed by a person with the proper minneapolis installer competency card employed by the minneapolis licensed permit applicant. 2. Existing mechanical code violations to be corrected at time of installation. *homeowners applying for in-floor heating must be approved by the mechanical reviewer ** HVAC equipment is allowed as a permitted obstruction in a required side or rear yard only when zStatus: finalType: MechanicalApplicant: Natalie S ReciputiEffective Date: 2014-02-04Permit Number: BLDG335099
February 3, 2014
Description: Miscellaneous HVAC work (no burners)Status: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Home Safety Solutions IncApplicant: R J Katz & N S ReciputiFees: $84Effective Date: 2014-02-03Permit Number: 4106462
May 10, 2013
Project Name: Wire Furnace AC & GfiStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Spark Electric COApplicant: Natalie ReciputiFees: $40Effective Date: 2013-05-10Permit Number: ELE1206-01689
May 10, 2013
Project Name: Savers Switch InstallationStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Hunt Electric CorporationApplicant: Natalie ReciputiFees: $40Effective Date: 2013-05-10Permit Number: ELE1301-05421
June 26, 2012
Description: MECH MECH | Scope of work: INSTALL BRYANT 88000 BTU FURNACE(HEAT LOSS 68235 BTU) AND 2 TON A/C(HEAT GAIN 26666 BTU) AS REPLACEMENTS Heating load calculation forms for furnaces and boilers installed in single family homes or duplexes are required to be left at the job site along with the homeowner package of information that includes the design, testing, and installation instructions. Contractors should be using manual J residential load calculations hand written or software designed. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf HVAC equipment is allowed as a permitted obstruction in a required side or rear yard as follows: Air-conditioning systems, heating, ventilating, and filtering equipment, not to exceed four (4) feet in height and adjacent to a nonresidential use or adjacent to a residential use which isStatus: completeType: MechanicalBusiness Name: Standard Heating & Air Conditioning IncApplicant: Natalie S ReciputiEffective Date: 2012-06-26Permit Number: BLDG354454
June 12, 2012
Description: Install bryant 88000 btu furnace(heat loss 68235 btu) and 2 ton a/c(heat gain 26666 btu) as replacementsStatus: DoneType: MechanicalSub Type: BtmaBusiness Name: Standard Heating & Air ConditioningApplicant: R J Katz & N S ReciputiFees: $168Effective Date: 2012-06-12Permit Number: 4106194
March 11, 2010
Description: *IRC1-R/R CONVERT DUPLEX DWELLING TO SFD. REMOVE 2ND FLOOR KITCHEN AND REMODEL FOR (DMH#2) 2 BEDROOM AND 3/4 BATH. INSTALL (2) 2 X 8 HEADER IN BEDROOM FOR SLIDING PATIO DOOR TO EXISTING LANDING AND STEPS. NEW PARTITION FRAMING FOR CLOSETS AND AROUND STAIR OPENING. CEMENT, FIBER-CEMENT, OR GLASS MAT GYPSUM BACKERS SHALL BE USED IN TUB AND SHOWER AREAS PER MFR RECOMMENDATIONS PER 2006 IRC 702.4.2 INSTALL INSULATION AND VAPOR BARRIER TO EXTERIOR CONDITIONS. 1 SAC CREDIT - FORM COMPLETED. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. THIS WORK MUST BE COMPLETED BY A LICENSED CONTRACTOR IN A MULTI-FAMILY DWELLING. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in Job Value: $13,352Status: completeType: ResidentialBusiness Name: Farrell & SonsApplicant: Natalie S ReciputiEffective Date: 2010-03-11Permit Number: BLDG27900
March 11, 2010
Description: *IRC1-R/R ADD FOOTING AND POST FOR BEARING AND INCREASE HEADER SIZE AT BEDROOM FOR SFD (JAG # 2) REVISION TO BIRE 3056322 EXISTING PERMIT. POST IS AT CORNER OF CLOSET ON SECOND FLOOR CARRIED TO NEW FOUNDATION. HEADER IS FOR 6-2 OPENING AT BEDROOM # 1 (NE BEDROOM 2ND FLOOR) AN ADDITIONAL 9-1/4 LVL IS BEING SISTERED TO EXISTING BEAM AT STAIR OPENING AND EXISTING CONNECTING BEAM IS BEING REBUILT. SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, AND HEATING/AIR CONDITIONING/VENTILATION WORK. THIS WORK MUST BE COMPLETED BY A LICENSED CONTRACTOR IN A MULTI-FAMILY DWELLING. CARBON MONOXIDE ALARMS REQUIRED IN ACCORDANCE WITH MN. STAT. 299F.50 IRC 313.2.1. When interior alterations, repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings, smoke detection shall be installed: A. on each level of the house B. in each bedroom C. in the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall notJob Value: $500Status: completeType: ResidentialBusiness Name: Farrell & SonsApplicant: Natalie S ReciputiEffective Date: 2010-03-11Permit Number: BLDG27909
August 4, 2009
Description: plumbing fix specify the type of fixtures by entering the quantity in the list below: water closets_1___ urinals_____ bathroom tubs____ basins_1___ sinks_____ wash trays_____ showers__1___ floor drains____ extensions_____ misc fixtures____ electric water heaters_____ other: specify below owner's name _________________ phone# ______________Status: completeType: plumbingBusiness Name: Randy Lane & Sons Plbg & HtgApplicant: Natalie S ReciputiEffective Date: 2009-08-04Permit Number: BLDG457935
November 14, 2008
Description: Addition footing and post for bearing and increase header size at bedroom for single family dwelling (jag # 2)Job Value: $500Status: DoneType: RemodelingSub Type: BireBusiness Name: Farrell And SonsApplicant: R J Katz & N S ReciputiFees: $66Effective Date: 2008-11-14Permit Number: 3056609
November 12, 2008
Description: Specify the type of fixtures by entering the quantity in the list below:Status: DoneType: plumbingSub Type: BtpaBusiness Name: Randy Lane & Sons Plbg & HtgApplicant: R J Katz & N S ReciputiFees: $97Effective Date: 2008-11-12Permit Number: 5100471
October 30, 2008
Description: Convert duplex dwelling to single family dwelling. Remove 2nd floor kitchen and remodel for (dmh#2)Job Value: $13,352Status: DoneType: RemodelingSub Type: BireBusiness Name: Farrell And SonsApplicant: R J Katz & N S ReciputiFees: $430Effective Date: 2008-10-30Permit Number: 3056322
September 10, 2001
Description: Windows replace 6 window inserts in home within existing openingsStatus: finalType: ResidentialApplicant: Natalie S ReciputiEffective Date: 2001-09-10Permit Number: BLDG203882
July 19, 2001
Description: Replace 6 window inserts in home within existing openingsJob Value: $4,290Status: DoneType: Building over the counterSub Type: BotcBusiness Name: Renewal By AndersenApplicant: R J Katz & N S ReciputiFees: $113Effective Date: 2001-07-19Permit Number: 1037177
July 24, 2000
Description: plumbing 3/4 water meterStatus: completeType: plumbingBusiness Name: Weld & Sons Plbg CoApplicant: Natalie S ReciputiEffective Date: 2000-07-24Permit Number: BLDG546541
September 22, 1999
Description: 3/4 water meterStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Weld & Sons Plbg CoApplicant: R J Katz & N S ReciputiFees: $40Effective Date: 1999-09-22Permit Number: 5005848
April 15, 1997
Description: Reroof w/tearoffJob Value: $7,335Status: DoneType: BuildingSub Type: BApplicant: R J Katz & N S Reciputi0Effective Date: 1997-04-15Permit Number: 639828
January 1, 1900
Description: Replacing window glass (2)Job Value: $700Status: completeType: ResidentialBusiness Name: Restoration Professionals MNApplicant: Megan M GiddingsFees: $85Effective Date: 1900-01-01Permit Number: BLDG799352

Current Ownership

Information about the current owner(s).

Property History

876 Se 18th Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 876 Se 18th Ave

School Information

Public/private schools serving 876 Se 18th Ave

Neighborhood

This property is located in University, Minneapolis, MN 55414.

Market Trends

Historical market data near 876 Se 18th Ave over selected time period.

Nearby Properties on 18th Ave