09/23/2013
Sold Price
$235,000$246/ft²

911 Se 21st Ave
Minneapolis, MN 55414

911 Se 21st Ave, Minneapolis, MN 55414 is a 5 bed, 2 bath, 955 ft² house built in 1922 on a 0.130 acre lot with 15 construction permits. This house is currently off market, and it was last sold in 2013 for $235,000. The latest TopHap estimate of the house's value is $261,552.

Property Valuations

Latest estimates for 911 Se 21st Ave based on TopHap automated valuation model (AVM).

Permits

911 Se 21st Ave has 15 permit records of total value of $62,150.

Permit History
15
Permits
$62,150
Total Permit Value
August 28, 2013
Description: PLUMB 2 BASIN, 1 FLOOR DRAIN, 1 SHOWER, 1 SINK, 2 TOILETS, 1 DISHWASHER, 1 STANDPIPE, Properly plug the unused plumbing openings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbing materials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbing contractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with Minnesota Statute 299F.50. Please refer to the following website for additional information. http://www.dli.mn.gov/CCLD/PDF/bc_websmoke_co_06_07.pdf Plans approved by both the State of Minnesota Department of Health and the Department of Labor and Industry are required to be on site for all plumbing work conducted in hospitals, nursing homes, supervised living facilities, outpatient surgical centers, boardinStatus: completeType: PlumbingBusiness Name: At Plumbing Heating & AirApplicant: Jeffrey P PetersonEffective Date: 2013-08-28Permit Number: BLDG523960
August 27, 2013
Description: *irc1-r/r remove existing center bearing wall at main floor of single family dwelling and install (3) 10 lvls (dmh#2) with 3 new posts and footings in basement under new posting locations at main floor. Separate permits are required for electrical plumbingand heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedrooms. Exceptions: 1. Smoke alarms in existing areas shall not be required to be interconnected and hardwired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure unless there is a crawl space or basement available which could provide access for hardwiring and interconnecStatus: finalType: ResidentialApplicant: Jeffrey P PetersonEffective Date: 2013-08-27Permit Number: BLDG41794
August 21, 2013
Description: | Scope of work: HVAC WORK AND ENTIRE SYSTEM REPLACEMENT ** IDENTIFY NUMBER OF EACH OF THE EXISTING INDIVIDUAL HEATING/COOLING SYSTEM BEING REPLACED, THAT SERVES AN INDIVIDUAL DWELLING UNIT. INDICATE THE NUMBER OF SYSTEMS THAT APPLY: _X_REMOVE EXISTING SYSTEM AND INSTALL NEW (BOILER OR FORCED AIR SYSTEM) __INSTALL NEW DUCTWORK, FURNACE, AND AC REQUIRED FOR INSPECTION 1. HVAC EQUIPMENT MUST BE SIZED TO ACCA MANUAL J OR AN EQUIVALENT METHOD. HEAT LOSS CALCULATIONS TO BE LEFT NEXT TO APPLIANCES FOR INSPECTION. OVER-SIZING OF HEATING EQUIPMENT MUST NOT EXCEED 43% AND COOLING EQUIPMENT MUST NOT EXCEED 21%. 2. DOCUMENTS RELATIVE TO MAINTENANCE AND STARTUP TESTING (ORSAT) SHALL BE AFFIXED TO THE MECHANICAL EQUIPMENT. 3. ALL WORK DONE UNDER THIS PERMIT MUST BE COMPLETED BY A PERSON WITH THE PROPER MINNEAPOLIS INSTALLER COMPETENCY CARD EMPLOYED BY THE MINNEAPOLIS LICENSED PERMIT APPLICANT. 4. EXISTING MECHANICAL CODE VIOLATIONS TO BE CORRECTED AT TIME OF INSTALLATION. ** HVAC EQUIPMENT IS ALLOWStatus: completeType: MechanicalBusiness Name: Swift Heating & Air Conditioning IncApplicant: Jeffrey P PetersonEffective Date: 2013-08-21Permit Number: BLDG340130
August 13, 2013
Project Name: BonjeanDescription: Get power back on remodel basementStatus: finalType: Ele exst 1 or 2 familySub Type: Residential exstBusiness Name: Driven Electric INCApplicant: Blake BonjeanFees: $40Effective Date: 2013-08-13Permit Number: ELE1304-01826
August 13, 2013
Project Name: Rehab Project Bsmt Bedrms Bathrm & Kitchen Roughin & FinishStatus: finalType: Ele new 1 or 2 familySub Type: Residential newBusiness Name: M Jones Electric LLCApplicant: Blake BonjeanFees: $280Effective Date: 2013-08-13Permit Number: ELE1304-02685
July 2, 2013
Description: HVAC work and entire system replacementStatus: DoneType: HVAC alterationsSub Type: BtmbBusiness Name: Swift MechanicalApplicant: Jeffrey P PetersonFees: $207Effective Date: 2013-07-02Permit Number: 4103370
April 15, 2013
Description: 2 basin 1 floor drain 1 shower 1 sink 2 toilets 1 dishwasher 1 standpipeStatus: DoneType: plumbingSub Type: BtpaBusiness Name: At Plumbing Heating & AirApplicant: Jeffrey P PetersonFees: $421Effective Date: 2013-04-15Permit Number: 5152230
April 8, 2013
Description: Remove existing center bearing wall at main floor of single family dwelling and install (3) 10 lvls (dmh#2)Job Value: $4,500Status: DoneType: RemodelingSub Type: BireBusiness Name: Matthew Kraskey ConstructionApplicant: Jeffrey P PetersonFees: $258Effective Date: 2013-04-08Permit Number: 3083768
March 29, 2013
Description: Basement finish to single family dwelling for 3 bedroom study room and 3/4 bathroom. (dmh#2)Job Value: $28,000Status: DoneType: RemodelingSub Type: BireBusiness Name: Matthew Kraskey ConstructionApplicant: Jeffrey P PetersonFees: $784Effective Date: 2013-03-29Permit Number: 3083613
June 9, 2011
Description: plumbingreplace 1 toilet properly plug the unused plumbingopenings at the nearest live main or branch on the waste and vent system. Cement is not an acceptable method of disconnect. Approved plumbingmaterials must be used. Dead ends are not permitted except where necessary to extend piping for a cleanout so as to be accessible. The work must be done by a licensed plumbingcontractor in which a permit and inspection is required before concealing. Carbon monoxide detectors are required in dwelling units in accordance with minnesota statute 299f.50. Please refer to the following website for additional information. Http://www.doli.state.mn.us/pdf/bcs_co_detectors_joint_memo_july06.pdf plans approved by both the state of minnesota department of health and the department of labor and industry are required to be on site for all plumbingwork conducted in hospitals nursing homes supervised living facilities outpatient surgical centers boarding care homes and residential hospice facilitiesStatus: finalType: PlumbingApplicant: Jeffrey P PetersonEffective Date: 2011-06-09Permit Number: BLDG470874
April 24, 2010
Description: Replace 1 toiletStatus: DoneType: plumbingSub Type: BtpaBusiness Name: United States Mechanical, IncApplicant: Jeffrey P PetersonFees: $72Effective Date: 2010-04-24Permit Number: 5116053
April 13, 1999
Description: Install 1 wt 1 gas rangeStatus: DoneType: plumbingSub Type: BtpaBusiness Name: Randy Lane & Sons Plbg & HtgApplicant: Jeffrey P PetersonFees: $120Effective Date: 1999-04-13Permit Number: 5002226
April 13, 1999
Description: plumbing install 1 wt 1 gas rangeStatus: completeType: plumbingBusiness Name: Randy Lane & Sons Plbg & HtgApplicant: Jeffrey P PetersonEffective Date: 1999-04-13Permit Number: BLDG578702
December 22, 1998
Description: Instl 1bt 1sk s-1wc 1bnJob Value: $1,650Status: DoneType: plumbingSub Type: DApplicant: Kenwood Venture Ptrnrs Llc0Effective Date: 1998-12-22Permit Number: 960207
January 1, 1900
Description: *irc1-r/r basement finish to single family dwelling for 3 bedroom study room and 3/4 bathroom. (dmh#2) install new egress window & well at one locaton. 2 other egress existing. Install 2x framing rigid insulation and drywall finishes. Remodel kitchen cabinets and counters only. Install cement backer board for ceramic tile at tub/shower locations and drywall finishes elsewhere. Smoke detectors and carbon monoxide detectors shall be installed and operable at the time the building inspector performs the final inspection for this permit. Separate permits are required for electrical plumbing and heating/air conditioning/ventilation work. Carbon monoxide alarms required in accordance with mn. Stat. 299f.50 irc 313.2.1. When interior alterations repairs or additions require a building permit or when one or more sleeping rooms are added or created in existing dwellings smoke detection shall be installed: a. On each level of the house b. In each bedroom c. In the hall or room outside of bedroomJob Value: $28,000Status: completeType: ResidentialBusiness Name: Matthew Kraskey ConstructionApplicant: Minneapolis Mn 55414 2511Effective Date: 1900-01-01Permit Number: BLDG39977

Current Ownership

Information about the current owner(s).

Property History

911 Se 21st Ave has undefined property events records (listings, deeds, permits, tax, foreclosure, loan).

Property Events

Environment

Environmental factors around 911 Se 21st Ave

School Information

Public/private schools serving 911 Se 21st Ave

Neighborhood

This property is located in University, Minneapolis, MN 55414.

Market Trends

Historical market data near 911 Se 21st Ave over selected time period.

Nearby Properties on 21st Ave